    PDB2PQR troubleshooting

    Fix PDB2PQR runs: dropped HETATM ligands and non-standard residues, surprising PROPKA pKa values, DEBUMP clash failures, and timeouts above 10,000 atoms.

    When PDB2PQR fails to prepare a structure or produces unexpected output, this page covers the common failure modes — from PDB fetch errors and missing atoms to surprising protonation states, steric-clash resolution, force-field gaps for non-standard residues, and timeouts on large structures.

    PDB2PQR troubleshooting

    PDB ID not found

    Symptom: "Could not fetch PDB structure" error.

    Fixes:

    • Verify the PDB ID is correct (four alphanumeric characters)
    • Check that the structure exists on RCSB PDB
    • Recently deposited structures may not be available yet. Upload the PDB file directly instead.

    Missing atoms in output

    Symptom: Output PQR has fewer atoms than expected, or warnings mention missing residues.

    Causes:

    • Disordered regions: Crystal structures often have missing density for flexible loops. PDB2PQR cannot model completely missing residues.
    • Non-standard residues: Modified amino acids may lack force field parameters and get dropped.
    • Ligand not included: PDB2PQR does not parameterize ligands — HETATM records without force-field parameters are dropped. Protonate the receptor here, then handle ligand parameterization with a dedicated cheminformatics tool.

    Fix: Check the warnings array in the output for specific messages about dropped atoms.

    Unexpected protonation states

    Symptom: A residue is protonated/deprotonated contrary to expectation.

    Explanation: PROPKA predicts pKa based on the local electrostatic environment. Buried residues, salt bridges, or hydrogen bond networks can shift pKa values significantly from model compound values.

    Verification:

    • Check the pKa table to see if the predicted value is near the target pH (borderline cases)
    • Compare with experimental pKa data if available
    • Visualize the residue environment to understand the electrostatic context

    DEBUMP fails with steric clashes

    Symptom: "Could not resolve steric clashes" warning.

    Fixes:

    • Set debump: false if you do not need clash resolution (some downstream tools handle this)
    • The steric clash may indicate a genuine structural issue (crystal packing artifact, alternate conformations)
    • Try processing a single chain with chain_ids to reduce complexity

    Force field errors for non-standard residues

    Symptom: "No parameters found for residue XXX" warning.

    Explanation: Non-standard residues (selenomethionine, modified amino acids, ligands) may not be parameterized in the selected force field.

    Fixes:

    • Try a different force field (CHARMM has broader residue coverage for some modifications)
    • Remove non-standard atoms from the structure before uploading it — PDB2PQR does not have a built-in flag for this
    • For ligands, use dedicated parameterization tools and merge the parameters manually

    Large structure takes too long

    Symptom: Job exceeds timeout for structures with > 10,000 atoms.

    Fixes:

    • Process a single chain with chain_ids
    • Enable remove_water: true to reduce atom count
    • Disable hydrogen-bond optimization (optimize_hydrogen_bonds: false) for faster processing (less accurate hydrogen placement)

    Getting help

    If issues persist:

    1. Check the job logs for specific warning messages
    2. Validate your PDB file with the RCSB validation server
    3. Describe the issue to Ivy